|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
- 2026-25-A1FLF
- Bourns
-
1.000:
9,92 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-25-A1FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,92 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
250 V
|
3 Electrode
|
|
Failsafe Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 250VOLT
- 2026-25-C2FLF
- Bourns
-
1.000:
9,85 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-25-C2FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 250VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,85 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
250 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
- 2026-25-C3FLF
- Bourns
-
1.000:
9,92 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-25-C3FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,92 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
250 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 250VOLT
- 2026-25-CBLF
- Bourns
-
1:
14,92 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-25-CBLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 250VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
14,92 kr.
|
|
|
12,76 kr.
|
|
|
10,29 kr.
|
|
|
8,73 kr.
|
|
|
View
|
|
|
8,58 kr.
|
|
|
6,74 kr.
|
|
|
6,37 kr.
|
|
|
6,06 kr.
|
|
|
6,03 kr.
|
|
Min.: 1
Mult.: 1
|
|
|
2026
|
40 kA
|
250 V
|
3 Electrode
|
|
Failsafe Not Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
- 2026-25-CLF
- Bourns
-
1.000:
7,18 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-25-CLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 250V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
7,18 kr.
|
|
|
7,06 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
250 V
|
3 Electrode
|
|
Failsafe Not Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
- 2026-26-C2FLF
- Bourns
-
1.000:
10,07 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-26-C2FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
260 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 260V 3 POLE
- 2026-26-C2LF
- Bourns
-
1.000:
6,74 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-26-C2LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 260V 3 POLE
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,74 kr.
|
|
|
6,61 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
260 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
13 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
- 2026-26-C3FLF
- Bourns
-
1.000:
9,92 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-26-C3FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,92 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
260 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
- 2026-26-C3LF
- Bourns
-
1.000:
6,86 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-26-C3LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 260V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,86 kr.
|
|
|
6,54 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
260 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 260VOLT
- 2026-26-CLF
- Bourns
-
1.000:
7,18 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-26-CLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 260VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
7,18 kr.
|
|
|
7,12 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
260 V
|
3 Electrode
|
|
Failsafe Not Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 300V 3 Pole
- 2026-30-C18
- Bourns
-
1.000:
7,76 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C18
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 300V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
7,76 kr.
|
|
|
7,53 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
|
17.8 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
- 2026-30-C2FLF
- Bourns
-
1.000:
10,00 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C2FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
10,00 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
- 2026-30-C2LF
- Bourns
-
1.000:
6,86 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C2LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,86 kr.
|
|
|
6,61 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
13 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 300V 3 Pole
- 2026-30-C3FLF
- Bourns
-
1.000:
10,07 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C3FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 300V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
10,07 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
- 2026-30-C3LF
- Bourns
-
1.000:
6,74 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C3LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,74 kr.
|
|
|
6,61 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
- 2026-30-C4LF
- Bourns
-
1.000:
6,86 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-30-C4LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 300VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,86 kr.
|
|
|
6,54 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
300 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3-Pole 90V
- 2026-35-A1FLF
- Bourns
-
1.000:
9,85 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-A1FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3-Pole 90V
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,85 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
|
Failsafe Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
- 2026-35-C3FLF
- Bourns
-
1.000:
9,92 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-C3FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
9,92 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
- 2026-35-C3LF
- Bourns
-
1.000:
6,74 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-C3LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,74 kr.
|
|
|
6,67 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
- 2026-35-C4FLF
- Bourns
-
1.000:
10,29 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-C4FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 350V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 350VOLT
- 2026-35-C4LF
- Bourns
-
1.000:
6,86 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-C4LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 350VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
6,86 kr.
|
|
|
6,74 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 350VOLT
- 2026-35-CLF
- Bourns
-
1.000:
7,12 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-35-CLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 350VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
7,12 kr.
|
|
|
6,99 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
350 V
|
3 Electrode
|
|
Failsafe Not Protected
|
7.9 mm
|
11.3 mm
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 400VOLT
- 2026-40-C2FLF
- Bourns
-
1.000:
10,07 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-40-C2FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors GAS DISCHARGE TUBE 3POLE 400VOLT
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
10,07 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
400 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 400V 3 Pole
- 2026-40-C3FLF
- Bourns
-
1.000:
10,07 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-40-C3FLF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 400V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
|
10,07 kr.
|
|
|
9,62 kr.
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
400 V
|
3 Electrode
|
Radial
|
Failsafe Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|
|
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 400V 3 Pole
- 2026-40-C3LF
- Bourns
-
1.000:
6,86 kr.
-
Non-Stocked Lead-Time 5 Weeks
|
Mouser Part No
652-2026-40-C3LF
|
Bourns
|
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 100V/s 400V 3 Pole
|
|
Non-Stocked Lead-Time 5 Weeks
|
|
Min.: 1.000
Mult.: 100
|
|
|
2026
|
40 kA
|
400 V
|
3 Electrode
|
Radial
|
Failsafe Not Protected
|
7.9 mm
|
|
- 40 C
|
+ 90 C
|
Bulk
|
|